MG REFINING & MARKETING, INC -- GASOLINE -- 9130-01-282-2844
===================== Product Identification ===================== Product ID:GASOLINE MSDS Date:05/01/1986 FSC:9130 NIIN:01-282-2844 === Responsible Party === Company Name:MG REFINING & MARKETING, INC Address:1100 MILAM ST SUITE 4750 City:HOUSTON State:TX ZIP:77002 Country:US Info Phone Num:800-824-4456 Emergency Phone Num:800-824-4456 CAGE:0BAM3 === Contractor Identification === Company Name:MG REFINING & MARKETING/METALLGESELLSCHAFT CORP Address:5 LAKE FANNY DR Box:1367 City:BEL AIR State:MD ZIP:21014-1367 Country:US Phone:800-882-9067/800-424-9300(CHEMTREC) CAGE:0BAM3 Company Name:MG REFINING AND MARKETING,INC Address:1100 MILAM ST SUITE 4750 Box:1367 City:HOUSTON State:TX ZIP:77002 Country:US Phone:800-882-9067/800-424-9300(CHEMTREC) CAGE:0S764 ============= Composition/Information on Ingredients ============= Ingred Name:BENZENE (SARA III) CAS:71-43-2 RTECS #:CY1400000 Fraction by Wt: UP TO 2% Other REC Limits:NONE RECOMMENDED OSHA PEL:1PPM/5STEL;1910.1028 ACGIH TLV:10 PPM; A2; 9293 EPA Rpt Qty:10 LBS DOT Rpt Qty:10 LBS Ingred Name:TOLUENE (SARA III) CAS:108-88-3 RTECS #:XS5250000 Fraction by Wt: UP TO 3% Other REC Limits:NONE RECOMMENDED OSHA PEL:200 PPM/150 STEL ACGIH TLV:50 PPM; 9293 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:XYLENES (O-,M-,P- ISOMERS) (SARA III) CAS:1330-20-7 RTECS #:ZE2100000 Fraction by Wt: UP TO 5% Other REC Limits:NONE RECOMMENDED OSHA PEL:100 PPM/150 STEL ACGIH TLV:100 PPM/150STEL;9293 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:TETRAETHYL LEAD Fraction by Wt: 0.1% Other REC Limits:NONE RECOMMENDED ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES Health Hazards Acute and Chronic:NONE SPECIFIED BY MANUFACTURER. Explanation of Carcinogenicity:BENZENE IS A KNOWN HUMAN CARCINOGEN THAT IS REGULATED BY NTP, IARC AND OSHA. Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER. Medical Cond Aggravated by Exposure:PERSONNEL WITH PRE-EXISTING SKIN DISORDERS, IMPAIRED LIVER OR KIDNEY FUNCTION, OR CENTRAL NERVOUS SYSTEMS & CHRONIC RESPIRATORY DISEASE SHOULD AVOID EXPOSURE TO THIS MATERIAL. ======================= First Aid Measures ======================= First Aid:INHALATION-MOVE PERSONNEL TO FRESH AIR. GIVE AIR, OXYGEN OR ADMINISTER CPR. IF NEEDED, OBTAIN MEDICAL ATTENTION. EYE-FLUSH EYES WITH CLEAN WATER, LOW PRESSURE FOR 15 MIN. SKIN-IF CLOTHING IS SOAKED, R EMOVE CLOTHING & WASH SKIN WITH SOAP & WATER. INGESTION-DO NOT INDUCE VOMITING, SINCE ASPIRATION INTO LUNGS WILL CAUSE CHEMICAL PNEUMONIA. PROMPTLY OBTAIN MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:-45F,-43C Autoignition Temp:Autoignition Temp Text:536F Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, OR FOAM. WATER STREAM MAY SPREAD FIRE; USE WATER ONLY TO COOL FIRE EXPOSED CONTAINERS. Fire Fighting Procedures:IF LEAK OR SPILL HAS NOT IGNITED, USE WATER SPRAY TO DISPERSE THE VAPORS. VAPOR IS HEAVIER THAN AIR & MAY TRAVEL CONSIDERABLE DISTANCE TO IGNITIONS & FLASHBACK. Unusual Fire/Explosion Hazard:CAN FORM FLAMMABLE MIXTURES WITH AIR & FLASH AT ROOM TEMPERATURES. EXPLOSION HAZARD IN FIRE SITUATION. ================== Accidental Release Measures ================== Spill Release Procedures:NOTIFY EMERGENCY RESPONSE PERSONNEL. EVACUATE AREA & REMOVE IGNITION SOURCES. DIKE SPILL. REMOVE FREE LIQUID, DO NOT FLUSH INTO SEWER OR OPEN WATER.BLANKET WITH FOAM OR USE WATER FOG TO DISPERSE VAPOR S. PICK UP WITH PADS & ABSORBENT MATERIALS. Neutralizing Agent:NA ====================== Handling and Storage ====================== Handling and Storage Precautions:KEEP CONTAINERS CLOSED & DO NOT STORE IN A CLOSED VEHICLE. CONTAINERS SHOULD BE ABLE TO WITHSTAND PRESSURES EXPECTED FROM WARMING/COOLON IN STORAGE. Other Precautions:STORAGE: STORE AS AN OSHA 1B FLAMMABLE LIQUID. HANDLING: GROUND ALL DRUMS & TRANSFER VESSELS WHEN HANDLING. EMPTY CONTAINERS RETAIN SOME LIQUID/VAPOR RESIDUE; HAZARD PRECAUTIONS MUST BE OBSERVED WHEN HANDLING EMPTIES. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:NONE NEEDED UNDER NOREMAL CONDTIONS WITH ADEQUATE VENTILATION. USE NIOSH/MSHA APPROVED RESPIRATOR WHEN VAPOR LEVELS EXCEED EXPOSURE LIMITS. UP TO 1000 PPM, HALF-MASK ORGANIC VAPOR RESPIRATOR. ****CONT INUES IN SUPPLEMENTAL DATA**** Ventilation:MAINTAIN LOCAL OR DILUTION VENTILATION TO KEEP AIR CON. BELOW 300 PPM. WHEN LOADING, UNLOADING, TANK GAUGING, ETC. Protective Gloves:NEOPRENE OR NITRILE RUBBER GLOVES Eye Protection:CHEMICAL GOGGLES WITH SIDE SHIELDS. Other Protective Equipment:GLOVES, APRONS, BOOTS & FACUIAL PROTECTION MADE OF NITRILE, NEOPRENE, ETC. EMERGENCY EYE WASH AND SAFETY SHOWER NEARBY. Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE. Supplemental Safety and Health UP TO 5000 PPM, FULL-FACE ORGANIC VAPOR RESPIRATOR OR FULL-FACE SUPPLIED AIR RESPIRATOR. GREATER THAN 5000 PPM, FIRE FIGHTING, OR UNKNOWN CONCENTRATIONS, SELF-CONTAINED BREATHING APPARATUS WITH POSITI VE PRESSURE. ================== Physical/Chemical Properties ================== HCC:F2 Boiling Pt:B.P. Text:70.0F,21.1C Decomp Temp:Decomp Text:NA Vapor Pres:325-525 Vapor Density:3-4 AIR=1 Spec Gravity:0.7-0.73 pH:NA Viscosity:NA Evaporation Rate & Reference: 1.5 Solubility in Water:NEGLIGIBLE Appearance and Odor:CLEAR, STRAW COLORED BRONZE OR PINKISH IN COLOR. Percent Volatiles by Volume:100% Corrosion Rate:NA ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG ACIDS OR STRONG OXIDIZERS. Stability Condition to Avoid:HEAT, SPARKS, FLAMES AND STATIC ELECTRICITY. Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD CARBON MONOXIDE, CARBON DIOXIDE, LEAD OXIDE & VARIOUS HYDROCARBONS. ==================== Disposal Considerations ==================== Waste Disposal Methods:MAXIMIZE PRODUCT RECOVERY FOR REUSE/RECYCLING. UNUSED LIQUID IS LIKELY AN EPA "IGNITABLE HAZARDOUS WASTE" (D001). USE APPROVED TREATMENT, TRANSPORTERS & DISPOSAL SITES IN COMPLIANCE WITH ALL LAWS. A P OTENTIAL DISPOSAL METHOD IS INCINERATIN/LANDFILL. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.